Tianhui- unus e primoribus UV DUCTUS fabricatores chippis et commeatus ODM/OEM UV ductus ministerii chippis praebet.

UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 1
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 2
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 3
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 4
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 5
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 6
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 1
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 2
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 3
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 4
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 5
UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 6

UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis

    Me paenitet ...!

    productum sine notitia.

    ad homepage
    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 7

    Descriptiona

    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 8

    TH-UVC-F27 sterilizer stabilis est applicata aeri et aquae sterilitate UVC DUXERIT sterilizationis moduli. Maxime apta est ad structuram spatialem cum piscina aqua clausa. In summo, pariete latere et fundo aquae piscinae institui potest, cum levibus output superficies postulata IP68 IMPERVIUS occurrat. Necem vagandi UVC LED usus 270-280nm est.

    Habet optimum et efficacem sterilizationem et disinfection- nem effectum. Altus vicus permeability vitreum adhibitum operculum instructum cum rationabili consilio optical ad vitandam sterilizationem mortuorum angulorum quantum fieri potest, idealis sterilizationis effectum consequi. Omnes materiae ad tutelam environmental requisitis ROHS occurrent et perveniunt.

    Omnes aquae partes pertinentibus requisitis cibum salutis et aquae batch

    Opportuna

    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 9
    Apparatus bibens Pet aqua dispensator   Aer humidifier

    Discilavator

    Aer Purificans   Machina glacies

    Morbi laoreet

    Elementum

    Specification

    Animadverte

    Modelus

    TH-UVC-F27

    -

    Aperti univers

    27.3±0.3mm

    per foramen

    Ventae

    DC 12Vor DC24V

    _Pertae

    Flux radiationis UVC

    4-6mW

    -

    Undes UVC

    260-280nm

    -

    Quotulli

    40Mar

    Secundum DUXERIT lectio

    Potturs intre

    0.2-0.4W

    Secundum DUXERIT lectio

    Grada aquaproum

    IP65

    Superficies polita plene IMPERVIUS

    Vieo

    500±10mm

    Linea longitudo potest nativus

    Terminal

    XH2.54, Blanca

    Terminationes potest nativus

    Vita lampaa

    10.000-25.000 horas

    Secundum DUXERIT lectio

    Dieelectrica fortitudo

    DC500 V,1min@10mA, Leakage current

    Grandio

    φ38 x 19.6 mm

    Net pondus

    26±5g


    opus temperatus

    -25℃-40℃

    -

    Repono temperatus

    -40℃-85℃

    -

    Rementara

    • Picus necem λ p) Mensura tolerantia est ±3nm.

    • Radiatio flux( Φ e) Mensuratio tolerantiae ± 10%.

    • Mensura tolerantiae intentionis anterioris (VF) est ± 3%.

    Altiore dimensionis

    • Module size - φ38 x 19.6 (Diameter x altitudo)

    • tolerantia ±0.5mm

    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 10

    Modus usus

    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 11

    Packaging modum (vexillum referat notitia)

    UVC DUXERIT Static Bacteriostatic Module TH-UVC-F27 Aquae Aeris Sterilizationis 12

    Monitum instructiones ad usus

    1. Ad vitandam labem industriae, frontem vitream mundam custodi.

    2. Commendatur non habere objecta lucis ante modulum interclusio, quae sterilizationis effectum afficiet.

    3. Quaeso utere recta intentione initus ad hunc moduli depellendum, alioquin modulus laedetur.

    4. Foramen exitu moduli glutino repletum est, quod aquam lacus prohibere potest, sed non est

    Commendatur ut glutinum foraminis exitu moduli aquam bibentem directe attingat.

    5. Noli positivos et negativos polos moduli vicissim coniungere, alioquin modulus laedi potest

    6. Humana salus

    Patefacio ut lux ultraviolacea damnum oculis humanis causare potest. Noli respicere lumen ultraviolaeum directe vel indirecte.

    Si detectio radiorum ultraviolatarum vitari nequit, machinis congruis tutelae ut goggles et vestis debet esse

    corpus tueri solebat. Documenta sequenti documento affigere ad products / systemata  